Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun StorageTek™6140 ArrayRelease NotesRelea
2 Sun StorageTek 6140 Array Release Notes • November 2008Features in This ReleaseThis section describes the main features of the Sun StorageTek 6140 A
Sun StorageTek 6140 Array Release Notes, Release 6.2 36140 Array Ship Kit ContentsThe Sun StorageTek 6140 Array controller and expansion trays are shi
4 Sun StorageTek 6140 Array Release Notes • November 2008Management SoftwareThe Sun StorageTek Common Array Manager software provides you with an easy
Sun StorageTek 6140 Array Release Notes, Release 6.2 5The following licenses for premium features are available from Sun:System RequirementsThe softwa
6 Sun StorageTek 6140 Array Release Notes • November 2008Disk Drives and Tray CapacityTABLE 4 lists the size, speed, and tray capacity for the support
Sun StorageTek 6140 Array Release Notes, Release 6.2 7Multipathing SoftwareYou must install multipathing software on each data host that communicates
8 Sun StorageTek 6140 Array Release Notes • November 2008Supported Host Bus Adaptors (HBAs)TABLE 6, TABLE 7, TABLE 8, and TABLE 9 lists supported HBAs
Sun StorageTek 6140 Array Release Notes, Release 6.2 9You must install the multipathing software before you install any OS patches.TABLE 6 Supported S
10 Sun StorageTek 6140 Array Release Notes • November 2008TABLE 7 Supported Microsoft Windows Data Host PlatformsHost OSPatches orServicePack Servers
Sun StorageTek 6140 Array Release Notes, Release 6.2 11Windows 200332-bitSP1 R2 x86 (IA32) Qlogic QLE 256xQlogic QLE 246xQLogic QLA 246xQLogic QLA 234
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, Inc. has intel
12 Sun StorageTek 6140 Array Release Notes • November 2008Windows 200364-bitSP1 R2 x64 (AMD)EM64TIA64Qlogic QLE 256xQlogic QLE 246xQLogic QLA 246xQLog
Sun StorageTek 6140 Array Release Notes, Release 6.2 13Windows 2008 ServicePack 1x86 (IA32)x64 (AMD)EM64TIA64QLogic QLE 256xQLogic QLA 246xQLogic QLE
14 Sun StorageTek 6140 Array Release Notes • November 2008TABLE 8 Supported Linux Data Host PlatformsHost OSPatches orService Pack HBAsClusterConfigur
Sun StorageTek 6140 Array Release Notes, Release 6.2 15Linux SuSE 9.0 -IA 32, 2.6 kernelSP4 QLogic QLE 256xQLogic QLA 246xQLogic QLE 246xQLogic QLA 23
16 Sun StorageTek 6140 Array Release Notes • November 2008Red Hat Linux 4.0,2.6 kernel- QLogic QLE 256xQLogic QLA 246xQLogic QLE 246xQLogic QLA 2310/2
Sun StorageTek 6140 Array Release Notes, Release 6.2 17Red Hat Linux 3.0,2.4 kernel- QLogic QLA 246xQLogic QLA 2342QLogic QLA 2340QLogic QLA 2310FEmul
18 Sun StorageTek 6140 Array Release Notes • November 2008Note – The multipathing driver for the IBM AIX platform is Veritas DMP, bundled in VeritasVo
Sun StorageTek 6140 Array Release Notes, Release 6.2 19Supported Enterprise SoftwareThe enterprise software applications listed in TABLE 10 are compat
20 Sun StorageTek 6140 Array Release Notes • November 2008Supported FC and Multilayer SwitchesThe following FC fabric and multilayer switches are comp
Sun StorageTek 6140 Array Release Notes, Release 6.2 21If the software detects that there is no earlier version installed, it will perform acomplete n
iiiContents1. Sun StorageTek 6140 Array Release Notes, Release 6.2 1Features in This Release 2Sun StorageTek 6140 Array Features 26140 Array Ship Kit
22 Sun StorageTek 6140 Array Release Notes • November 2008Updating the SSD Driver for the Solaris OSAfter installing software for the data hosts from
Sun StorageTek 6140 Array Release Notes, Release 6.2 23113277-44/README.113277-444. Apply the patch with the patchadd command.patchadd 113277-445. Reb
24 Sun StorageTek 6140 Array Release Notes • November 2008Workaround – Download the following patch and follow the patch instructions toinstall it on
Sun StorageTek 6140 Array Release Notes, Release 6.2 25Hardware and Firmware IssuesThis section describes general issues related to the Sun StorageTek
26 Sun StorageTek 6140 Array Release Notes • November 2008Controller Cache Memory Size Displays 0Bug 6747153 – When running controller firmware versio
Sun StorageTek 6140 Array Release Notes, Release 6.2 27With Release 5.0, the Sun StorageTek 6140 Array Getting Started Guide (Release 2.0) hasbeen rep
28 Sun StorageTek 6140 Array Release Notes • November 2008 Heat Output:410 Watts (1400 BTU/Hr) using AC Power Source445 Watts (1519 BTU/Hr) using DC
Sun StorageTek 6140 Array Release Notes, Release 6.2 29Workaround - To avoid having the array incorrectly initiate a volume migrationprocess with the
30 Sun StorageTek 6140 Array Release Notes • November 2008To connect from a portable PC without a serial port, you will need to purchase a USBto seria
Sun StorageTek 6140 Array Release Notes, Release 6.2 31FF – IOM Boot Diagnostic executing88 – This IOM is being held in Reset by the other IOMAA – IOM
iv Sun StorageTek 6140 Array Release Notes • November 2008Known Issues 23Installation and Initial Configuration Issues 23Hardware and Firmware Issues
32 Sun StorageTek 6140 Array Release Notes • November 2008You can search for this documentation online athttp://www.sun.com/documentation.Service Cont
Sun StorageTek 6140 Array Release Notes, Release 6.2 33Third-Party Web SitesSun is not responsible for the availability of third-party web sites menti
34 Sun StorageTek 6140 Array Release Notes • November 2008
35CHAPTERADisk Drive InsertionThis appendix describes how to properly insert a disk drive into a controller orexpansion tray.Drives are inserted with
36 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE A-1 Inserting a Disk Drive.When the drive is completely installed, the drive and hand
Chapter A Disk Drive Insertion 37FIGURE A-2 Successfully Inserted Disk DriveCaution – Do not insert a disk drive into a tray by pushing on its housing
38 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE A-3 Incorrect Way to Insert Disk Drive
39CHAPTERBUsing DC PowerThis appendix describes using the DC Power Unit for the Sun StorageTek 6140 arrayin the following sections: “DC Power Overvie
40 Sun StorageTek 6140 Array Release Notes • November 2008Caution – A qualified service person is required to make the DC power connectionper NEC and
Chapter B Using DC Power 41FIGURE B-2 DC Power Connector Cable and Source WiresSite Preparation for DC PowerThis section updates the Sun StorageTek 61
Contents vInstalling a Tray in a Telco 2-Post Rack 55
42 Sun StorageTek 6140 Array Release Notes • November 2008Note – Power for the optional –48-VDC power configuration is supplied by acentralized DC pow
Chapter B Using DC Power 43DC Power Connector Cables and Source WiresThe Sun StorageTek 6140 array is shipped with –48-VDC power connector cables ifth
44 Sun StorageTek 6140 Array Release Notes • November 2008Ship Kit ChangesIf the DC power option is ordered, two DC power connector cables are provide
Chapter B Using DC Power 45Connecting Power CablesTo use the DC power option (–48-VDC) to power the array module, review thefollowing points. Ensure
46 Sun StorageTek 6140 Array Release Notes • November 2008Note – It is not mandatory that the second DC power connection on each of thearray module’s
Chapter B Using DC Power 47Caution – Potential data loss – Moving a array or array components that areconfigured as part of a volume group can result
48 Sun StorageTek 6140 Array Release Notes • November 2008
49CHAPTERCPreparing the Two-Post Telco RackUse the procedures in this chapter to install trays in a standard Telco rack. (You canuse the existing univ
50 Sun StorageTek 6140 Array Release Notes • November 2008Preparing the Telco RackInstall the rack as described in the installation instructions provi
Chapter C Preparing the Two-Post Telco Rack 51FIGURE C-1 Inserting Screws in the Front and Back Mounting Holes2. Align the open slot of the left mount
vi Sun StorageTek 6140 Array Release Notes • November 2008
52 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE C-2 Seating the Mounting Rails Over the Front and Back Screws3. Insert eight more (12
Chapter C Preparing the Two-Post Telco Rack 53FIGURE C-3 Inserting Screws in the Lower Mounting Holes
54 Sun StorageTek 6140 Array Release Notes • November 20084. Using the #3 Phillips screwdriver, tighten all twelve screws (three on each sideof a post
Chapter C Preparing the Two-Post Telco Rack 55Installing a Tray in a Telco 2-Post RackWhen installing a tray in a Telco 2-post rack, follow these inst
56 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE C-6 Positioning the Tray in the Rack3. Carefully slide the tray onto the mounting rai
Chapter C Preparing the Two-Post Telco Rack 574. Use the #2 Phillips screwdriver to insert and tighten four 10-32 x 1/2 screws,washers, and nuts (two
58 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE C-8 Securing the Tray to the Front of the Rack5. Replace the left and right end caps
Chapter C Preparing the Two-Post Telco Rack 59FIGURE C-9 Securing the Tray to the Back of the Rack8. Tighten the four10-32 locknuts (two on each rail)
60 Sun StorageTek 6140 Array Release Notes • November 2008FIGURE C-10 Tightening the Locknuts on the Rail Extension.
viiTablesTABLE 1 Comparison of 2GB Cache and 4GB Cache Array Configurations 2TABLE 2 Supported Expansion Modules - 6000 Series Arrays 4TABLE 3 Availab
viii Sun StorageTek 6140 Array Release Notes • November 2008
1Sun StorageTek 6140 ArrayRelease Notes, Release 6.2This document contains important release information about the Sun StorageTek™6140 Array or inform
Kommentare zu diesen Handbüchern