ISR651101-00 HiSR6200QLogic intelligent Storage Router (iSR)Installation Guide
x ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideList of FiguresFigure Page1-1 Remote SAN Island Connectivity . . . .
5–Fibre Channel over IPConfiguring FCIP5-2 ISR651101-00 H Links up to two locations per blade, four locations per chassis (two blades) FICON® suppo
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-3Table 5-1 provides space for you to write down the information that you must obtain prior to
5–Fibre Channel over IPConfiguring FCIP5-4 ISR651101-00 H MTU Size (0=Normal, 1=Jumbo, 2=Other) [Normal ] TCP Window Size (0=8KB, 1
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-510. At the TCP Window Size prompt, specify the window size for the WAN as determined in “TCP
5–Fibre Channel over IPConfiguring FCIP5-6 ISR651101-00 HFigure 5-1 shows an example of a single FCIP route (single ISL). Figure 5-1. E_Port Extensio
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-7Figure 5-2 shows an example of a two FCIP routes (dual ISLs). This example assumes that the
5–Fibre Channel over IPConfiguring FCIP5-8 ISR651101-00 HFigure 5-3 shows an example of F_Port extension used to connect a remote storage array.Figur
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-9Figure 5-4 shows an example of F_Port extension used to connect a remote (stranded) server.F
5–Fibre Channel over IPConfiguring FCIP5-10 ISR651101-00 HRound-Trip TimeRTT is the time required for a packet to travel from the sender to the recei
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-11Link Data RateThe available link data rate is not typically the same as the connection spee
ISR651101-00 H xiiSR6200 QLogic intelligent Storage Router (iSR)Installation Guide4-25 Host LUN Access with LUN Masking Disabled . . . . . . . . .
5–Fibre Channel over IPConfiguring FCIP5-12 ISR651101-00 H TCP Retransmit Timer Expired—The sender of a packet did not receive an ACK for a packet w
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-13 MAC Xmit Bytes 1534059818 MAC Xmit Multi Count 6 MAC Xmit
5–Fibre Channel over IPConfiguring FCIP5-14 ISR651101-00 HTo verify the listen port number, run the following command (from a Linux system), where th
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-15Data CompressionData compression is an option that in some configurations can provide a dat
5–Fibre Channel over IPConfiguring FCIP5-16 ISR651101-00 HTable 5-4. T1 / DS-1—1.554MbpsRound-Trip Time(ms)Window Size(bytes)Scaling Factor(2n)250 64
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-17Table 5-6. DS-5—400MbpsRound-Trip Time(ms)Window Size(bytes)Scaling Factor(2n)250 8M or 16M
5–Fibre Channel over IPConfiguring FCIP5-18 ISR651101-00 HTable 5-8. OC-3—150MbpsRound-Trip Time(ms)Window Size(bytes)Scaling Factor(2n)250 1M or 2M
5–Fibre Channel over IPConfiguring FCIPISR651101-00 H 5-19Table 5-10. OC-12 and Above—621MbpsRound-Trip Time(ms)Window Size(bytes)Scaling Factor(2n)2
5–Fibre Channel over IPConfiguring FCIP5-20 ISR651101-00 HRouter TCP Window SetupTable 5-12 contains router settings for the listed TCP window sizes.
ISR651101-00 H 6-16 Diagnostics and TroubleshootingDiagnostic information about the router is available through the chassis LEDs and the port LEDs. D
xii ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideList of TablesTable Page1-1 Internal Temperature Sensor Limits . .
6–Diagnostics and TroubleshootingPower-On Self-Test Diagnostics6-2 ISR651101-00 HInput Power LED is OffThe input power LED lights up to show that the
6–Diagnostics and TroubleshootingLED Blink PatternsISR651101-00 H 6-3All other system fault blink patterns show critical errors. The heartbeat LED sh
6–Diagnostics and TroubleshootingRecovering a Router6-4 ISR651101-00 HOver-Temperature Blink PatternThe system fault LED generates a five-blink patte
ISR651101-00 H 7-17 Removal and ReplacementThis chapter describes how to remove and replace the following FRUs: SFP Transceivers iSR6200 Chassis Bl
7–Removal and ReplacementiSR6200 Chassis Blades7-2 ISR651101-00 HThe blade replacement feature ensures that the replaced unit retains the MAC address
7–Removal and ReplacementiSR6200 Chassis BladesISR651101-00 H 7-33. Remove the old blade from the chassis. Figure 7-2 shows how to release the latch
7–Removal and ReplacementiSR6200 Chassis Blades7-4 ISR651101-00 H2. Insert the new blade into the chassis slot. Figure 7-4 shows how to push the blad
7–Removal and ReplacementiSR6200 Chassis BladesISR651101-00 H 7-5Removing the Failed BladeTo remove a failed blade from an iSR6200 chassis with a sin
7–Removal and ReplacementiSR6200 Chassis Blades7-6 ISR651101-00 H3. Use an FTP client to get the FRU file from the iSR6200 blade. For both the user n
7–Removal and ReplacementiSR6200 Chassis BladesISR651101-00 H 7-7Figure 7-5. iSR6200 Router Blade with Cables Disconnected5. Remove the old blade fro
ISR651101-00 H xiiiPrefaceThis user’s guide describes and provides installation procedures for the QLogic® iSR6200 Series intelligent Storage Router
7–Removal and ReplacementiSR6200 Chassis Blades7-8 ISR651101-00 HTo install a replacement blade in an iSR6200 chassis with a single blade:1. Unlatch
7–Removal and ReplacementiSR6200 Chassis BladesISR651101-00 H 7-9The system runs the POST. The heartbeat and system fault LEDs show the operational s
7–Removal and ReplacementPower and Cooling Modules7-10 ISR651101-00 HiSR6200 <1> (admin) #> fru restore A list of attributes with formattin
7–Removal and ReplacementPower and Cooling ModulesISR651101-00 H 7-11Removing the Failed PCMTo remove a failed PCM from the iSR6200 chassis:1. Locate
7–Removal and ReplacementPower and Cooling Modules7-12 ISR651101-00 HFigure 7-10. Removing the Failed PCMInstalling the Replacement PCMTo install a r
7–Removal and ReplacementPower and Cooling ModulesISR651101-00 H 7-13Figure 7-12. Inserting the Replacement PCM3. Connect the power cable to the newl
7–Removal and ReplacementPower and Cooling Modules7-14 ISR651101-00 H
ISR651101-00 H A-1A Technical SpecificationsThis appendix provides the following technical specification for the iSR6200 router: Interface Specifica
A–Technical SpecificationsExpansion ConfigurationsA-2 ISR651101-00 H Management Ports: Ethernet 10 or 100 Base-T with RJ45 RS-232 serial port with
A–Technical SpecificationsiSCSI Initiator SupportISR651101-00 H A-3iSCSI Initiator Support Microsoft: Windows 2000, 2003, and 2008 Solaris: SPARC 2
xiv ISR651101-00 H Chapter 6 Diagnostics and Troubleshooting provides system diagnostic and troubleshooting tools available for the iSR6200 router.
A–Technical SpecificationsHigh AvailabilityA-4 ISR651101-00 H Power Supply: 235W maximum (two blades and two expansion cards) 106W typical (one bl
A–Technical SpecificationsEnvironmental and SafetyISR651101-00 H A-5 Non-operating: Temperature: -40°C to +70°C (-40°F to158°F) Humidity: 5 percen
A–Technical SpecificationsEnvironmental and SafetyA-6 ISR651101-00 H
ISR651101-00 H B-1B Simple Network Management ProtocolSimple network management protocol (SNMP) provides monitoring and trap functions for managing t
B–Simple Network Management ProtocolSNMP ParametersB-2 ISR651101-00 HSNMP ParametersYou can set the SNMP properties using SANsurfer Router Manager or
B–Simple Network Management ProtocolSNMP Trap ConfigurationISR651101-00 H B-3SNMP Trap ConfigurationSNMP trap configuration lets you set up to eight
B–Simple Network Management ProtocolManagement Information Base (MIB)B-4 ISR651101-00 HNetwork Port TableThe network port table contains a list of ne
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-5qsrNwPortRole qsrNwPortIndex qsrNwPortAddressMode qsrIPAddress
B–Simple Network Management ProtocolManagement Information Base (MIB)B-6 ISR651101-00 HqsrNetMask qsrGateway qsrMacAddress qstNwLinkStatus qsrNwLinkR
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-7FC Port TableThis table contains a list of the Fibre Channel (
ISR651101-00 H xv Internet engineering task force (IETF): iSCSI Requirements and Design Considerations, iSCSI Naming and Discovery, Internet Protoco
B–Simple Network Management ProtocolManagement Information Base (MIB)B-8 ISR651101-00 HqsrFcPortRole qsrFcPortIndex qsrFcPortNodeWwn qsrFcPortWwn qsr
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-9qsrFcPortType qsrFcLinkStatus qsrFcLinkRate Initiator Object T
B–Simple Network Management ProtocolManagement Information Base (MIB)B-10 ISR651101-00 HqsrIsInitEntry iSCSI initiator information entry consists of
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-11qsrIsInitAddressType qsrIsInitAddress qsrIsInitStatus qsrIsIn
B–Simple Network Management ProtocolManagement Information Base (MIB)B-12 ISR651101-00 HLUN TableThese tables contains information about the logical
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-13qsrLunVendorId qsrLunProductId qsrLunProdRevLevel qsrLunSize
B–Simple Network Management ProtocolManagement Information Base (MIB)B-14 ISR651101-00 HqsrLunVPGroupid qsrLunVPGroupname OBJECT-TYPE VP Group TableT
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-15qsrVPGroupIndex OBJECT-TYPEqsrVPGroupId OBJECT-TYPEqsrVPGroup
B–Simple Network Management ProtocolManagement Information Base (MIB)B-16 ISR651101-00 HSensor TableThe sensor table lists all the sensors on the rou
B–Simple Network Management ProtocolManagement Information Base (MIB)ISR651101-00 H B-17qsrSensorIndex qsrSensorUnits qsrSensorValueqsrUpperThreshold
xvi ISR651101-00 H WARNING indicates the presence of a hazard that could cause serious injury or death. Te xt in blue font indicates a hyperlink
B–Simple Network Management ProtocolNotificationsB-18 ISR651101-00 HqsrSensorStateNotificationsThe router provides the following notification types d
B–Simple Network Management ProtocolNotificationsISR651101-00 H B-19qsrSerialNumber qsrHwVersion qsrSwVersion qsrNoOfFcPorts qsrNoOfGbEPorts qsrAgent
B–Simple Network Management ProtocolNotificationsB-20 ISR651101-00 HNotification ObjectsThis section defines the objects used in notifications.qsrEve
B–Simple Network Management ProtocolNotificationsISR651101-00 H B-21Network Port Down NotificationThe network port down notification indicates that t
B–Simple Network Management ProtocolNotificationsB-22 ISR651101-00 H Target WWPN Blade number (1 or 2)Target Presentation (Mapping)The target prese
B–Simple Network Management ProtocolNotificationsISR651101-00 H B-23 qsrEventTimeStamp qsrEventSeveritySensor notifications are sent for the follow
B–Simple Network Management ProtocolNotificationsB-24 ISR651101-00 HGeneric NotificationThe generic notification reports events other than the define
ISR651101-00 H C-1C Log MessagesThis appendix provides details about messages logged to a file. (For details about viewing the router logs, see the i
C–Log MessagesC-2 ISR651101-00 H TOE = TCP/IP offload engine module User = User module The Msg. Type column specifies the log message type, where:
C–Log MessagesISR651101-00 H C-341077 QLBA_CreateInitiatorObject: Too many initiatorsApp Error Unable to create an object for initiator object; excee
ISR651101-00 H xviiCommunications StatementsThe following statements apply to this product. The statements for other products intended for use with t
C–Log MessagesC-4 ISR651101-00 H41268 QLIS_LoginPduContinue: Missing target nameApp Error iSCSI Login PDU received without a target name for a normal
C–Log MessagesISR651101-00 H C-541508 QLBI_SetPortInfo: QLUT_AllocatePortalObject failed (PortType 0x%x, PortId 0x%x)App Error Failed to allocate an
C–Log MessagesC-6 ISR651101-00 H41717 QLBI_Passthru: Invalid data length %d bytesApp Error Pass-Through command issued by management application (suc
C–Log MessagesISR651101-00 H C-742027 QLFC_Logout: VP Index 0x%x not configured App Error Logout attempted using Fibre Channel VP index that has not
C–Log MessagesC-8 ISR651101-00 H42649 QLIS_HandleTeb: Unload Driver App Error Event notification; an IOCTL request was received to unload the iSCSI d
C–Log MessagesISR651101-00 H C-954274 QLFC_Login: Origin 0x%x, VP Index 0x%x, Id 0x%xApp Info Fibre Channel login occurred, origin xx (1 = adapter, 2
C–Log MessagesC-10 ISR651101-00 H54939 QLIS_HandleTeb: UTM_EC_CLOSE_CONNECTION or UTM_EC_CONNECTION_CLOSEDApp Info Event notification; iSCSI close co
C–Log MessagesISR651101-00 H C-1156842 QLDM_ResumeMigration: Failed to resume job: %d, job's current state: 0x%x, error: %dApp Info Failed to re
C–Log MessagesC-12 ISR651101-00 H56880 Start time got from user %lu Cur Time: %lu Diff: %dApp Info The log shows the configured start time and curren
C–Log MessagesISR651101-00 H C-1369966 #%d: QLEnable: QLRebootTimer failed AF %x RS %x Time %diSCSI Fatal Port enable reboot timer failed.70224 #%d:
xviii ISR651101-00 HCE StatementThe CE symbol on the equipment indicates that this system complies with the EMC (Electromagnetic Compatibility) direc
C–Log MessagesC-14 ISR651101-00 H70524 #%d: QLProcessAen: Invalid event %x iSCSI Fatal Asynchronous event for unknown event type.70544 #%d: QLReboot
C–Log MessagesISR651101-00 H C-1573990 #%d: QLUtmIoctlEnable: Initialize FW failediSCSI Error The iSCSI processor failed firmware initialization.7405
C–Log MessagesC-16 ISR651101-00 H74659 #%d: QLReadyTimer: Adapter missed heartbeat for 0x%x secondsiSCSI Error The iSCSI processor (adapter) failed t
C–Log MessagesISR651101-00 H C-1786347 #%d: QLDisable: Restart RISC iSCSI Info Restart iSCSI processor (RISC).86349 #%d: QLEnable: Restart RISC to up
C–Log MessagesC-18 ISR651101-00 H102657 #%d: QLInitializeAdapter: Load RISC code failedFC Fatal Fibre Channel processor firmware load failed.102658 #
C–Log MessagesISR651101-00 H C-19102755 #%d: QLTimer: Heartbeat failed FC Fatal Fibre Channel processor heartbeat failed.102800 #%d: QLRestartRisc: r
C–Log MessagesC-20 ISR651101-00 H106851 #%d: QLTimer: Heartbeat failed FC Error The Fibre Channel controller failed to provide a heartbeat.106853 #%
C–Log MessagesISR651101-00 H C-21107078 #%d: QLUpdatePort 0x%x: out of slots in host databaseFC Error The driver was unable to re-establish connectio
C–Log MessagesC-22 ISR651101-00 H119089 #%d: QLIsrEventHandler: LIP reset occurred (%x): mailbox1 = %xFC Info Fibre Channel LIP reset occurred. The L
C–Log MessagesISR651101-00 H C-23120375 #%d: QLIsrEventHandler: IDC Notification (%x), %x, %x, %x, %x, %x, %x, %xFC Info For FCoE protocol, the IDC n
ISR651101-00 H xixVCCI Class A StatementThis is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If
C–Log MessagesC-24 ISR651101-00 H139271 QBRPC_Initialize:GetIsns Mem Allocation errorUser Error Get iSNS API memory allocation failed.139272 QBRPC_In
C–Log MessagesISR651101-00 H C-25139288 QBRPC_Initialize:Init Mem Allocation errorUser Error Failed memory allocation for Initiator API.139289 QBRPC_
C–Log MessagesC-26 ISR651101-00 H139305 QBRPC_Initialize:LunList MemAlloc error User Error Failed memory allocation for LUN List API.139315 QBRPC_Fre
C–Log MessagesISR651101-00 H C-27139936 FcipRoute#%d Failed with Persistence Write FailureUser Error Write of FCIP route definition to persistent mem
C–Log MessagesC-28 ISR651101-00 H151893 #%d: qapisetvlanparams_1_svc: VLAN configuration changedUser Info The VLAN configuration has changed.151894 q
C–Log MessagesISR651101-00 H C-29151913 qapimaptargetdevice_1_svc: Target WWPN: %.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x unmapped from iSCSI portal %d. User
C–Log MessagesC-30 ISR651101-00 H152105 qapireadjustpriority_1_svc: Readjust Priority DoneUser Info Completed readjusting the serial schedule priorit
C–Log MessagesISR651101-00 H C-31152137 sysTempMon: Slot 1 (R1) PCM Fan%d faulty User Info The left PCM (#1) is reporting a faulty fan.152138 sysTemp
C–Log MessagesC-32 ISR651101-00 H172238 FcipRoute#%d: Synchronization Error on ReceiveFCIP Error Indicates an error in the received FCIP PDU framing;
C–Log MessagesISR651101-00 H C-33172250 FcipRoute#%d: TCP Link Down FCIP Error The TCP link went down. Check the Ethernet cabling and Ethernet switch
ii ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideInformation furnished in this manual is believed to be accurate and
xx ISR651101-00 HElectrostatic Discharge Sensitivity (ESDS) PrecautionsThe assemblies used in the switch chassis are electrostatic discharge sensitiv
C–Log MessagesC-34 ISR651101-00 H204835 QL3xxx:eth%x PHY Downshift occurred TOE Error The Ethernet device could not successfully communi-cate with t
ISR651101-00 H Glossary-1Glossaryactivity LEDA port LED that indicates when frames are entering or leaving the port.adapterThe board that interfaces
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideGlossary-2 ISR651101-00 Hcomma separated values fileSee CSV file.command line inter
ISR651101-00 H Glossary-3iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideF_PortThe fabric port in a Fibre Channel fabric switch pro
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideGlossary-4 ISR651101-00 HFL_PortFabric loop port. In a Fibre Channel, the fabric sw
ISR651101-00 H Glossary-5iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideioctlInput/output control. A system call in UNIX®/Linux sy
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideGlossary-6 ISR651101-00 Hmanagement workstationPC workstation used to manage router
ISR651101-00 H Glossary-7iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideNTPNetwork time protocol. NTP is used for distributing the
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideGlossary-8 ISR651101-00 H Fibre Channel—a port in a fabric where an N_Port can att
ISR651101-00 H Glossary-9iSR6200 QLogic intelligent Storage Router (iSR)Installation Guidesmall form factorSee SFF.small form-factor pluggableSee SF
ISR651101-00 H xxi3. In the search results list, locate and select the firmware, software, or documentation for your product.4. View the product deta
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideGlossary-10 ISR651101-00 HVPGsVirtual port group. VPG is the iSR6200 software compo
ISR651101-00 H Index-1IndexAAC power 3-7activity LEDdefinition of Glossary-1port data indicator 1-14, 1-15port indicator 1-14, 1-15adaptercable for r
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-2 ISR651101-00 HCLIdefinition of Glossary-1installing firmware 3-16set vpgrou
ISR651101-00 H Index-3iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideenablingFCIP interfaces 5-4VPGs 4-2environmentalconditions 3-
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-4 ISR651101-00 HFRUsdefinition of Glossary-4removing/replacing 7-1FTP 2-9GG_P
ISR651101-00 H Index-5iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideiSCSIinitiator support A-3port LED 1-14definition of Glossary
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-6 ISR651101-00 Hmanagement information base, See MIBmappingLUNs 4-25targets B
ISR651101-00 H Index-7iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideOC-12definition of Glossary-7TCP windows sizes 2-6OC-3, TCP w
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-8 ISR651101-00 Hpre-configuration, FCIP 5-3presenting targets B-22process ide
ISR651101-00 H Index-9iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideRread community, setting SNMP properties B-2recovering a rout
xxii ISR651101-00 H
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-10 ISR651101-00 Hsensors (continued)lower-level threshold B-17unit of measure
ISR651101-00 H Index-11iSR6200 QLogic intelligent Storage Router (iSR)Installation Guidetables (continued)qsrFcPortId B-8qsrFcPortIndex B-8qsrFcPort
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideIndex-12 ISR651101-00 Htrapsauthentication, enabling B-2community, setting SNMP pro
Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.comInternational Office
ISR651101-00 H 1-11 IntroductionThis chapter illustrates and describes QLogic’s iSR6200 intelligent Storage Router (iSR), including the components co
1–IntroductionLicensed Features1-2 ISR651101-00 HLicensed FeaturesThe iSR6200 router has features that are available by a license key.Data MigrationT
1–IntroductioniSR6200 Router ChassisISR651101-00 H 1-3This configuration has the following additional requirements: At least one Fibre Channel port
1–IntroductioniSR6200 Router Chassis1-4 ISR651101-00 HThe iSR6200 router chassis contains one or two router blades, along with a PCM for each blade.
1–IntroductionPower and Cooling Module (PCM)ISR651101-00 H 1-5Power and Cooling Module (PCM)Each iSR6200 chassis blade has a PCM located on the backs
1–IntroductioniSR6200 Router Blades1-6 ISR651101-00 HTable 1-1 shows the internal temperature limits set to trigger events or server message block (S
1–IntroductioniSR6200 Router BladesISR651101-00 H 1-7The following sections illustrate and describe the physical features and functionality of the iS
iSR6200 QLogic intelligent Storage Router (iSR)Installation GuideISR651101-00 H iiiAdded new topology section and diagram. “Topology” on page 2-7Made
1–IntroductioniSR6200 Router Blades1-8 ISR651101-00 H IPv4 and IPv6 protocol support iSCSI header and data digest in the software Figure 1-7. 10GbE
1–IntroductioniSR6200 Router BladesISR651101-00 H 1-9Figure 1-8. iSCSI (GE) Ports on the iSR6240 Router BladeRouter Blade LEDsEach chassis blade prov
1–IntroductioniSR6200 Router Blades1-10 ISR651101-00 HInput Power LED (Green)The power LED shows the voltage status of the router logic circuit board
1–IntroductioniSR6200 Router BladesISR651101-00 H 1-11 “Enable DHCP” on page 1-12 “Restore Factory Defaults” on page 1-12Reset a Router BladeTo res
1–IntroductioniSR6200 Router Blades1-12 ISR651101-00 HEnable DHCPTo reset the router and configure the maintenance port to use dynamic host configura
1–IntroductioniSR6200 Router BladesISR651101-00 H 1-13Each port has three LEDs: The amber (top) LED shows activity for data passing through the por
1–IntroductioniSR6200 Router Blades1-14 ISR651101-00 HThe iSR6200 router supports SFP optical transceivers for the Fibre Channel ports. A transceiver
1–IntroductioniSR6200 Router BladesISR651101-00 H 1-15Figure 1-13. Ethernet Management PortA management workstation can be a Windows®, Solaris®, or a
1–IntroductioniSR6200 Router Blades1-16 ISR651101-00 H
ISR651101-00 H 2-12 PlanningThis chapter describes how to plan for the iSR6200 router. The following sections describe the devices and services you n
iv ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation Guide
2–PlanningDevice Access2-2 ISR651101-00 HDevice AccessConsider device access needs within the Fibre Channel and iSCSI SANs. Controlling access to Fib
2–PlanningiSCSI PerformanceISR651101-00 H 2-3Each Fibre Channel port is supported by a data buffer with a three-credit capacity; that is, three maxim
2–PlanningPerformance Tuning2-4 ISR651101-00 HLatencyLatency is a measure of how fast a transaction travels through the router and LAN or WAN.Perform
2–PlanningPerformance TuningISR651101-00 H 2-5 Table 2-2. T3—45MbpsRound-Trip Delay (ms) TCP Window Size (kbytes)≤ 1.4 8≤ 2.9 16≤ 5.7 32≤ 11.4 64≤ 22
2–PlanningPerformance Tuning2-6 ISR651101-00 HTable 2-4. OC-3—156MbpsRound-Trip Delay (ms) TCP Window Size (bytes)≤ 0.4 8≤ 0.8 16≤ 1.6 32≤ 3.3 64≤ 6.
2–PlanningTopologyISR651101-00 H 2-7TopologyThe iSR6200 router supports interconnecting remote SANs (see Figure 2-1).Figure 2-1. WAN Topology—Remote
2–PlanningRecovery2-8 ISR651101-00 HRecoveryYou should have a process in place to recover from a possible router failure. Consider the following when
2–PlanningSecurityISR651101-00 H 2-9 File transfer protocol (FTP) enables you to transfer files rapidly between the workstation and router using FTP
2–PlanningSecurity2-10 ISR651101-00 H
ISR651101-00 H 3-13 InstallationThis chapter describes how to install and configure an iSR6200 router, including: “Site Requirements” on page 3-1 “
ISR651101-00 H vTable of ContentsPrefaceIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
3–InstallationInstalling the iSR6200 Router3-2 ISR651101-00 HPower RequirementsThe iSR6200 router requires the following power supply: 235W maximum,
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-35. Connect the management workstation to the router (see page 3-8).6. Configure the mana
3–InstallationInstalling the iSR6200 Router3-4 ISR651101-00 HiSCSI port 4 IP address, subnet mask, and gateway for the optional (FC4, GE-4, or 10GE-4
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-5Mounting the RouterYou can either place the router on a flat surface or mount it in a 19
3–InstallationInstalling the iSR6200 Router3-6 ISR651101-00 HInstalling the TransceiversThe router supports a variety of SFP transceivers. To insta
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-7Connecting the Router to AC PowerFigure 3-1 shows the front and back plates of an iSR620
3–InstallationInstalling the iSR6200 Router3-8 ISR651101-00 HTo power on the router:1. Attach the AC power cord to the power connector, located on th
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-9 Direct Ethernet connection from the management workstation to the router RJ45 Ethernet
3–InstallationInstalling the iSR6200 Router3-10 ISR651101-00 HConfiguring the Workstation Serial PortTo configure the workstation serial port:1. Conn
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-11Where /dev/term/a refers to serial port a. Choose the dv setting to match the workstati
vi ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideiSR6200 Router Blades . . . . . . . . . . . . . . . . . . . . . . .
3–InstallationInstalling the iSR6200 Router3-12 ISR651101-00 HFigure 3-3 shows an example of the Search Support dialog box in Windows Internet Explor
3–InstallationInstalling the iSR6200 RouterISR651101-00 H 3-135. Under SANsurfer Router Manager for <operating system>, click the Download link
3–InstallationInstalling the iSR6200 Router3-14 ISR651101-00 H3. Double-click the install.app icon to start the installation wizard.4. Follow the pro
3–InstallationInstalling New FirmwareISR651101-00 H 3-15 Serial, Linux: Open a command window and enter the following command:minicom2. Open an admi
3–InstallationInstalling New Firmware3-16 ISR651101-00 H3. In the results box under Resource Name, click the router firmware that you want to install
3–InstallationInstalling New FirmwareISR651101-00 H 3-172. Enter your user name and password. For example:User (172.17.137.190:(none)): ftp331 Guest
3–InstallationInstalling New Firmware3-18 ISR651101-00 H
ISR651101-00 H 4-14 ConfigurationThis chapter describes how to configure the iSR6200 router to support virtual port groups (VPGroups or VPGs) and LUN
4–ConfigurationEnabling Virtual Port Groups4-2 ISR651101-00 HEnabling Virtual Port GroupsEach iSR6250 router blade has one virtual port group (VPG) e
4–ConfigurationEnabling Virtual Port GroupsISR651101-00 H 4-3Using SANsurfer Router Manager, select one of the VP Group nodes in the left pane to vie
ISR651101-00 H viiiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideManagement . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–ConfigurationEnabling Virtual Port Groups4-4 ISR651101-00 H2. In the Status list, select Enabled or Disabled (see Figure 4-2).Figure 4-2. Chassis I
4–ConfigurationEnabling Virtual Port GroupsISR651101-00 H 4-5To enable or disable a VPGroup using the CLI:The following example shows how to enable V
4–ConfigurationEnabling Virtual Port Groups4-6 ISR651101-00 HThe following example shows CLI command output using an iSR6200 blade with three virtual
4–ConfigurationEnabling Virtual Port GroupsISR651101-00 H 4-7The following example shows the information grouped by physical Fibre Channel port.iSR62
4–ConfigurationEnabling Virtual Port Groups4-8 ISR651101-00 H Port ID 0a-05-02 (VPGROUP_3) Firmware Revision No.
4–ConfigurationZoning Virtual Port Groups on the SANISR651101-00 H 4-9Zoning Virtual Port Groups on the SANWhen zoning the iSR6200 virtual port group
4–ConfigurationZoning Virtual Port Groups on the SAN4-10 ISR651101-00 HWhen connecting a single-bladed iSR6200 to two independent SANs, connect one F
4–ConfigurationZoning Virtual Port Groups on the SANISR651101-00 H 4-11When connecting a dual-blade iSR6200 for high availability, connect one Fibre
4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN Assignments4-12 ISR651101-00 HConfiguring Fibre Channel Array Hosts and LUN AssignmentsW
4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN AssignmentsISR651101-00 H 4-13Figure 4-9 illustrates this incorrect configuration.Figure
viii ISR651101-00 HiSR6200 QLogic intelligent Storage Router (iSR)Installation Guide5 Fibre Channel over IPFCIP Attributes . . . . . . . . . . . . .
4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN Assignments4-14 ISR651101-00 HIf you are using two blades in a high availability configu
4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN AssignmentsISR651101-00 H 4-15When assigning LUNs to your VPG host entities, do not assi
4–ConfigurationConnecting iSCSI Hosts to the iSR62004-16 ISR651101-00 HFigure 4-13 shows presenting LUN 3 incorrectly. If an iSCSI host logged into b
4–ConfigurationConnecting iSCSI Hosts to the iSR6200ISR651101-00 H 4-17The following example shows the anatomy of a sample IQN string from an iSR6200
4–ConfigurationConnecting iSCSI Hosts to the iSR62004-18 ISR651101-00 HTo view presented target information using SANsurfer Router Manager, expand th
4–ConfigurationConnecting iSCSI Hosts to the iSR6200ISR651101-00 H 4-19Enabling additional VP Groups creates multiple IQN strings for the same Fibre
4–ConfigurationConnecting iSCSI Hosts to the iSR62004-20 ISR651101-00 HiSR6200 <1> #> show vpgroups VpGroup Information ------------------
4–ConfigurationConnecting iSCSI Hosts to the iSR6200ISR651101-00 H 4-21 Alias <MAPS TO> WWNN 10:00:00:20:c2:07:59:70 WWPN 21:04:00:
4–ConfigurationConnecting iSCSI Hosts to the iSR62004-22 ISR651101-00 HIn Figure 4-15, the iSCSI host has logged into iSCSI target for VPG0. The host
4–ConfigurationControlling per-Host LUN Access on the iSR6200ISR651101-00 H 4-23In Figure 4-17, the iSCSI host has logged into iSCSI targets for both
ISR651101-00 H ixiSR6200 QLogic intelligent Storage Router (iSR)Installation GuideA Technical SpecificationsInterface Specifications . . . . . . .
4–ConfigurationControlling per-Host LUN Access on the iSR62004-24 ISR651101-00 HFigure 4-18 shows that even after logging into the VPG0 iSCSI target,
4–ConfigurationControlling per-Host LUN Access on the iSR6200ISR651101-00 H 4-25 Index (WWNN,WWPN/iSCSI Name) ----- ---------------------- 0
4–ConfigurationControlling per-Host LUN Access on the iSR62004-26 ISR651101-00 HTo map LUN 1 to an initiator using SANsurfer Router Manager:1. On the
4–ConfigurationControlling per-Host LUN Access on the iSR6200ISR651101-00 H 4-273. On the LUN Selection window, select LUN1 as shown in Figure 4-21,
4–ConfigurationControlling per-Host LUN Access on the iSR62004-28 ISR651101-00 HThe LUN Masking Configuration Status window lists the mapping request
4–ConfigurationControlling per-Host LUN Access on the iSR6200ISR651101-00 H 4-29Figure 4-23 uses color coding to identify the LUN mapping that became
4–ConfigurationControlling per-Host LUN Access on the iSR62004-30 ISR651101-00 HThe following example shows how to do this using the set system CLI c
4–ConfigurationControlling per-Host LUN Access on the iSR6200ISR651101-00 H 4-31Figure 4-24 shows how to enable LUN mapping on an iSR6200 blade 1. To
4–ConfigurationControlling per-Host LUN Access on the iSR62004-32 ISR651101-00 HFigure 4-25 shows host LUN access with LUN Mapping disabled. Figure 4
ISR651101-00 H 5-15 Fibre Channel over IPFibre Channel over IP (FCIP) is a protocol used to transport Fibre Channel frames over TCP/IP, thus providin