Release Notes for Sun Storage 6580 and 6780 Arrays 17
Tray ID Diagnostic Codes
See Appendix C, Troubleshooting and Operational Procedures, in the Hardware
Installation Guide for Sun Storage 6580 and 6780 Arrays for a description of the
controller tray and expansion tray diagnostic codes.
Documentation Issues
This section describes issues related to Sun Storage 6580 and 6780 Arrays
documentation.
Upgrade Guide Does Not Include Instructions for Battery Age Reset
Bug CR 6887119 When upgrading a Sun StorageTek 6540 array to a Sun Storage
6580 or 6780 array, the Sun Storage 6000 Series Hardware Upgrade Guide does not
include the step to reset the battery age after the upgrade. Not resetting the battery
age could prompt premature battery replacement due to misreported age
information.
Workaround Use the Service Advisor battery replacement procedure to reset the
battery age after the upgrade.
Total Cache Size Specification for Sun Storage 6780 Array
In Table 1-1 of the Hardware Installation Guide for Sun Storage 6580 and 6780 Arrays
(820-5773-11), the value for “Total cache size” is reported as “16 Gbytes or 32
Gbytes.” As of the CAM 6.6 release, the revised value is “8, 16, 32, or 64 Gbytes.” The
revised value is documented in
TABLE 1 of this release note document.