Qlogic QLA2100F Spezifikationen Seite 166

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 243
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 165
v CHS Mapping: [SCSI Plug and Play Mapping]
v Spinup Delay (Secs): [2]
v Secondary Cluster Server: [No]
v Termination Control: [Auto]
v Restore Defaults: (restores defaults)
f. Set the parameters on the Device Properties panel as follows:
v MT or Sec: [20]
v Data Width: [16]
v Scan ID: [Yes]
v Scan LUNs >0: [Yes]
v Disconnect: [On]
v SCSI Time-out: 240
v Queue Tags: [On]
v Boot Choice: [No]
v Format: [Format]
v Verify: [Verify]
v Restore defaults: (restores defaults)
g. Save the changes and select Symbios Configuration Utility again to verify
that you saved the changes.
7. Restart the server.
8. Load the Symbios driver, and restart the system if instructed to do so.
Installing and configuring the QLogic adapter card
Perform the following steps to install and configure the QLogic QLA1041 adapter
card.
Note: The parameter settings shown are an example. The settings for your
environment might be different.
1. Install the QLogic QLA1041 adapter card in the server.
2. Connect the cable to the ESS port.
3. Start the server.
4. Press Alt+Q to get to the FAST!Util menu.
a. From the Configuration Settings menu, select Host Adapter Settings. Set
the following parameters:
v Host Adapter: Enabled
v Host Adapter BIOS: Disabled
v Host Adapter SCSI ID: 7
v PCI Bus direct memory access (DMA) Burst: Enabled
v Compact disc Boot: Disabled
v SCSI Bus Reset: Enabled
v SCSI Bus Reset Delay: 5
v Concurrent Command or Data: Enabled
v Drivers Load RISC Code: Enabled
v Adapter Configuration: Auto
b. Set the parameters in the SCSI Device Settings menu as follows:
v Disconnects OK: Yes
140 ESS Host Systems Attachment Guide
Seitenansicht 165
1 2 ... 161 162 163 164 165 166 167 168 169 170 171 ... 242 243

Kommentare zu diesen Handbüchern

Keine Kommentare