Qlogic QLA2100F Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
performance. Maximum value may be less depending on the size of the
firmware.
Valid Values 1 - 750
Default Value 512
hba0-execution
Throttle Maximum number of commands sent to the LUN by the firmware.
Exceeding a device’s capabilities causes unnecessary command retries,
which impact performance.
Valid Values 1 - 65635
Default Value 20
hba0-login-retry-count
Maximum number of retries to attempt when login into a device fails.
Large values can cause long delays during initialization.
Valid Values 0 - 255
Default Value 8
hba0-enable-adapter-hard-loop-ID
Enables/disables the hard loop ID and activates (if enabled) the
setting for variable hba0-adapter-hard-loop-ID
Valid Values 0 (disable) or 1 (enable)
Default Value 1
hba0-adapter-hard-loop-ID
Sets (if activated) the hard loop ID for the HBA during the Loop
Initialization Process(LIP). If hba0-enable-adapter-hard-loop-ID and
hba0-adapter-hard-loop-ID are not set as shown in Table 9-3, the LIP
might fail and the host might not recognize the Symmetrix. These
variables become crucial in a hub environment, since no device
(Symmetrix target or host bus adapter) can have the same hard loop
ID. The host HBA is conventionally assigned the highest Hard Loop ID,
starting from 125 and working down (124, 123 122, etc.). The
Symmetrix is conventionally assigned a lowest Hard Loop ID for each
port, starting with 0 and working up (1, 2, 3, etc.). The following
example is a configuration for three QLA-2100F HBAs with separate
Hard Loop IDs:
# Adapter hard loop ID.
# Range: 0 - 126
hba0-adapter-hard-loop-ID=125;
hba1-adapter-hard-loop-ID=124;
hba2-adapter-hard-loop-ID=123;
Valid Values 1 - 125
Default Value 125
hba0-login-timeout
Login timeout (in seconds).
Valid Values 4 - 255 (sec)
Default Value 4
hba0-enable-extended-logging
Enables the driver extended error reporting capabilities.
Valid Values 0 (disable) or 1 (enable)
Default Value 0
hba0-enable-64bit-addressing
Seitenansicht 3