Qlogic Fibre Channel NPIV Storage Networking Guide Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Vernetzung Qlogic Fibre Channel NPIV Storage Networking Guide herunter. Qlogic Fibre Channel NPIV Storage Networking Guide Product specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 78
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FC0054608-00 A
FC0054608-00 A
Fibre Channel NPIV Storage Networking
for Windows Server 2008 R2 Hyper-V
and System Center VMM2008 R2
Usage Scenarios and Best Practices Guide
Seitenansicht 0
1 2 3 4 5 6 ... 77 78

Inhaltsverzeichnis

Seite 1 - FC0054608-00 A

FC0054608-00 A FC0054608-00 A Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2 Us

Seite 2

I-Deployment Best Practices for NPIV SAN Migration I-2 Notes

Seite 3 - Table of Contents

1-1 1 Introduction Abstract This guide describes procedures and best practices for planning and deploying N_Port ID Virtualization (NPIV)

Seite 4 - Part III

1-Introduction Microsoft Windows Server 2008 R2 Hyper-V 1-2 The deployment scenario in this document demonstrates NPIV VM migration in a SAN-att

Seite 5 - FC0054608-00 A v

1-Introduction System Center Virtual Machine Manager 1-3 Machine Manager 2008 R2, helps realize the vision of the dynamic data center. Follow t

Seite 6

1-Introduction N_Port ID Virtualization (NPIV) 1-4 This document focuses on NPIV SAN migration. N_Port ID Virtualization (NPIV) N_Port ID Virtu

Seite 7 - Preface

1-Introduction Value of NPIV in IT Strategy and Best Practices 1-5 Value of NPIV in IT Strategy and Best Practices Fibre Channel NPIV technolog

Seite 8 - Documentation Conventions

1-Introduction QLogic Fibre Channel Adapter NPIV Solution 1-6 With the combined QLogic and Microsoft solution, storage administrators can create

Seite 9 - SAN Migration

1-Introduction NPIV VMM2008 R2 SAN Migration Steps 1-7 NPIV VMM2008 R2 SAN Migration Steps The chart in How to Enable SAN Migration outlines th

Seite 10 - I-2

1-Introduction NPIV VMM2008 R2 SAN Migration Steps 1-8 Notes

Seite 11 - 1 Introduction

2-1 2 NPIV SAN Migration: Server Preparation This section list the hardware and software requirements that must be met before deploying t

Seite 12 - 1-2

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide ii

Seite 13 - 1-3

2-NPIV SAN Migration: Server Preparation Software Requirements 2-2 http://technet.microsoft.com/en-us/library/cc764224.aspx#UpTo Software Requir

Seite 14 - 1-4

2-NPIV SAN Migration: Server Preparation Sample Solution Configuration 2-3 Sample Solution Configuration Figure 2-1 Quick Migration Configurati

Seite 15 - 1-5

2-NPIV SAN Migration: Server Preparation Installing the Software 2-4 1. Install Windows Server 2003 R2 SP2 and set it up as the domain controll

Seite 16 - 1-6

2-NPIV SAN Migration: Server Preparation Installing the Software 2-5 3. Activate the required Windows Server 2008 R2 roles, services, and feat

Seite 17 - 1-7

2-NPIV SAN Migration: Server Preparation Installing the Software 2-6 Figure 2-4. Details of the Hyper-V Role

Seite 18 - 1-8

2-NPIV SAN Migration: Server Preparation Installing the Software 2-7 The installed server features are summarized in Figure 2-5. They are consi

Seite 19 - 2 NPIV SAN Migration:

2-NPIV SAN Migration: Server Preparation Installing the Software 2-8 NOTE: In addition to enabling the Multipath I/O feature, ensure that the st

Seite 20 - Software Requirements

3-1 3 Fibre Channel SAN Preparation Introduction This section assumes that you are familiar with QLogic‘s SANsurfer FC HBA Manager tool a

Seite 21 - Installing the Software

3-Fibre Channel SAN Preparation Virtual Host Bus Adapter Port Creation and SAN Zoning 3-2 Alternatively, the SAN can be configured as two zones,

Seite 22 - 2-4

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-3 The zoning configuration in Figure 3-2 shows two adapter ports:

Seite 23 - 2-5

iii Table of Contents Preface Intended Audience ... vii Documen

Seite 24 - 2-6

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-4 After creating a LUN, mount a volume in the LUN. (For more inform

Seite 25 - 2-7

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-5 In Figure 3-4, the LUN is mapped/presented/masked to the host 21

Seite 26 - Figure 2-6. MPIO Properties

3-Fibre Channel SAN Preparation Host Presentation (Mapping) of Storage LUN 3-6 View the Storage Manager for SANs snap-in to confirm that the LUN

Seite 27 - 3 Fibre Channel SAN

4-1 4 VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Microsoft System Center VMM2008 R2 is used for the creation and migration of

Seite 28 - 3-2

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-2 Figure 4-1. Hosts Added to VMM2008 R2 In Figure 4-1, the hosts win-3f1

Seite 29 - 3-3

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-3 VMM2008 R2 automatically mounts the appropriate volumes during the migr

Seite 30 - 3-4

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-4 In this example, a new VM will be created on a blank virtual hard disk (

Seite 31 - 21:f9:00:1b:32:16:fe:ec

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-5 4. Configure the hardware profile for the VM (see Figure 4-4). Figure

Seite 32 - 3-6

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-6 5. Click Next until the Select Destination dialog box opens. Ensure th

Seite 33 - 4 VMM2008 R2 Setup, VM

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-7 7 Click Next. The Select Path dialog box opens (see Figure 4-6). By d

Seite 34 - VM Creation

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide iv

Seite 35 - Figure 4-2. Select Source

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-8 Figure 4-7 is an example of the Summary page that displays the VM settin

Seite 36 - 4-4

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-9  Format the volume with the NTFS file system. When performing SAN tra

Seite 37 - 4-5

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Creation 4-10 Similarly, as shown in Figure 4-9, there are no VMs on the second host

Seite 38

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-11 VM Migration As shown in Figure 4-10, VM migration is invoked by righ

Seite 39 - Figure 4-6. Select Path

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-12 The Migration Virtual Machine Wizard opens and leads you through the f

Seite 40 - Figure 4-7. Summary

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-13 The Select Path dialog box opens (Figure 4-12). Figure 4-12. Select

Seite 41 - 4-9

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-14 4. Click Next when you are done. 5. The Summary dialog box opens (F

Seite 42 - 3fikc24knkr

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration VM Migration 4-15 7. Click Jobs to see the details of the migration (see Figure 4-14)

Seite 43 - VM Migration

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-16 NPIV SAN Migration Confirmation After migration, us

Seite 44 - 4-12

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-17 After migration, the selected VM (vm22) is now hos

Seite 45 - 4-13

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2 — Usage Scanarios and Best Practices Guide F

Seite 46 - Review the summary

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration NPIV SAN Migration Confirmation 4-18 Windows Server Disk Management validates that the v

Seite 47 - 4-15

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Using Fibre Channel NPIV Technology — Key Conclusions 4-19 Using Fibre Channel NPIV Tec

Seite 48 - (see Figure 4-15)

4-VMM2008 R2 Setup, VM Creation, and NPIV SAN Migration Using Fibre Channel NPIV Technology — Key Conclusions 4-20 Notes

Seite 49 - 4-17

II-1 Part II Resolving Fibre Channel Adapter Saturation on Hyper-V Workloads This part of the document contains the following section: 

Seite 50 - Figure 4-17)

II-Resolving Fibre Channel Adapter Saturation on Hyper-V Workloads II-2 Notes

Seite 51 - Conclusions

5-1 5 QLogic Management PRO Pack and NPIV Technology Overview Increasing server consolidation results in multiple workloads exercising t

Seite 52 - 4-20

5-QLogic Management PRO Pack and NPIV Technology Solution 5-2 http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/SearchByProduct.aspx?Pr

Seite 53

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits 5-3 A PRO Tip is generated when a virtual or physical port‘s IOPS or data ra

Seite 54 - II-2

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits with NPIV Deployments 5-4  Dynamic and automated IT agility  Single glass

Seite 55 - 5 QLogic Management PRO

5-QLogic Management PRO Pack and NPIV Technology PRO Pack Benefits with NPIV Deployments 5-5 Notes

Seite 56 - 5-2

Fibre Channel NPIV Storage Networking for Windows Server 2008 R2 Hyper-V and System Center VMM2008 R2─Usage Scenarios and Best Practices Guide vi

Seite 58 - 5-4

III-1 Part III Using the Hyper-V Pass-through Disk Option This part of the document contains the following section:  Section 6, Hyper-V

Seite 59 - 5-5

III-Using the Hyper-V Pass-through Disk Option III-2

Seite 60

6-1 6 Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Overview A Hyper-V host server running Windows Server 2008 R

Seite 61

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration 6-2 The combination of QLogic Fibre Channel adapters (with

Seite 62 - III-2

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-3 Configuration Steps Follow these steps to prese

Seite 63 - 6 Hyper-V Pass-Through

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-4 3. Create two VMs using the Windows Server 2008

Seite 64 - Configuration

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-5 4. Initialize the two storage LUNs on the Hype

Seite 65 - Configuration Steps

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-6 5. Add the LUNs as pass-through storage disks f

Seite 66 - 6-4

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-7 6. Map (present) each of the two VM LUNs to ea

Seite 67 - 6-5

vii Preface Intended Audience This guide is for data center system administrators and IT managers working with Microsoft® Windows Server®

Seite 68 - SCSI controller

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Configuration Steps 6-8 7. Map the two pass-through storage LUNs to the

Seite 69 - Port 21-F9-00-1B-32-16-FE-EC

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-9 NOTE: Ensure th

Seite 70 - 6-8

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-10 Figure 6-8. T

Seite 71 - Service

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-11 Figure 6-9.

Seite 72 - Channel Port 0

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-12 Figure 6-10.

Seite 73 - 6-11

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Viewing and Managing Storage I/O Quality of Service 6-13 Figure 6-11.

Seite 74 - 6-12

6-Hyper-V Pass-Through Storage and QLogic Fibre Channel NPIV Technology Summary and Conclusions 6-14 Figure 6-12. Priority (High/Medium/Low) B

Seite 76 - Summary and Conclusions

© 2009 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, and SANsurf

Seite 77

Preface Documentation Conventions viii  Click the Start button, point to Programs, point to Accessories, and then click Command Prompt.  Und

Seite 78

I-1 Part I Deployment Best Practices for NPIV SAN Migration This part of the document contains the following sections:  Section 1, Intro